Inspectors

The inspectors cannot do it alone!

Quality assurance and code inspections are the last measures to ensure a code compliant project relative to seismic bracing. However, unless construction documents are clear and specification sections concise, the contractor and inspectors are set up for failure.

ISAT understands the inspection community is not always empowered with the latest seismic code knowledge, the luxury of enough time or given the proper tools to effectively determine if a seismic bracing system is code compliant.

The ISAT system and approach is designed with these factors in mind. If you are responsible for code enforcement and would like further information about our services, contact ISAT and view other related sections of this site listed below.

ISAT Design, Installation and Inspection Manual

Code Education Seminars

Construction Oversight and Quality Assurance

Specification and Code Review

Code Information

Related Links

Inside ISAT

Hospital Experience?

Unmatched and Undeniable!

Year

# of Hospital Projects

Subcontractor Trades

2007
2006
2005

2004
2003

147 Hospital Projects
125 Hospital Projects
98 Hospital Projects
91 Hospital Projects
88 Hospital Projects

339 Separate MEP Trades
287 Separate MEP Trades
216 Separate MEP Trades
180 Separate MEP Trades
165 Separate MEP Trades

The seismic restraint of suspended HVAC ducts, fire protection piping, electrical utilities and plumbing/piping systems for hospital construction projects has been a daily function of ISAT for many years. Although we have a broad range of project types under our belt, we are extremely proud of our hospital experience.

If you are involved in healthcare construction, you are familiar with the issues that compound the process. Highly congested hospital corridors, more stringent code requirements and ambiguous inspection influences all complicate an already tricky construction project. Past experience has proven a solid understanding of inherent issues and a good base knowledge of the seismic bracing code requirements by the entire construction and design team, can drastically streamline issues surrounding seismic bracing code compliance.

Contact ISAT to provide the latest insight to streamline your scope of work regarding seismic bracing code compliance for the IBC 2000/2003 and OSHPD projects.

Key Aspects to Consider

The ISAT Design, Installation and Inspection Manual OPA-0485 is the most comprehensive OSHPD pre-approval in existence. Utilizing the ISAT OPA-0485 pre-approval, combined with our current OSHPD experience, has proven to be the single most effective tool in streamlining the OSHPD document review and plan approval process. Contact ISAT to learn more regarding our approach.

 

877.999.ISAT





ISAT Manuals

•  2006 IBC
•  2003 IBC
•  OSHPD OPA-0485


What's Hot

•  Elite Access
•  Code Seminars
•  ISAT's Resume
•  Employment


OSHPD Information

•  Non-Expiration
•  OSHPD FAQs
•  SB 1953 Services