Push Rod Hanger - PRSDI (Steel Deck Insert)

Push Rod Hanger PRSDI (Steel Deck Insert) - Multi Threaded Anchor Insert for Steel Concrete Decks

ISAT's Push Rod Steel Deck (PRSDI) inserts for pre-poured concrete: The Push Rod Overhead Attachment System features a revolutionary patented auto-lock chamber that locks in threaded rod. Push to engage, reverse thread to easily change rod sizes.

Installers will quickly realize the labor savings benefits of simply pushing threaded rod into the Push Rod Auto-Lock Insert instead of turn threading. The threaded rods feature patented Engagement Indicators that confirm full engagment. No second guessing, no installer error. Plus, just like the Blue Banger Hanger cousin, Push Rod Hanger’s reduce inventory because each insert accomodates multiple rod sizes that can be changed after installation.

PRSDI's are used on steel form poured decks and installed prior to pouring reducing installation costs, material costs and increasing strength values. Push Rod Hanger US Patent Numbers 6,240,697 B1 and 7,093,400 B1.

Just Push It!! Engineered to save you time and money.

  • No threading - simply PUSH ROD - saves labor costs
  • Fits both 3/8” and 1/2” threaded rod
  • Eliminates the need and cost of couplings
  • Backed by industry leading design and application engineering
  • No drilling concrete, no using rod couplers, no special inspection and no installer error

 

ISAT Brochure Learn More - Download the Push Rod Hanger Brochure

ISAT Brochure Download the ICC ESR-3599 Report

Reduce Labor Costs With ISAT's Patented Push Rod Hanger Insert. Click here to order Patented Push Rod Hanger inserts by phone or online.

ISAT is your number one resource for the Push Rod Hangers! Contact us to learn more.

Just Push It!! Patented Engagement Indicators confirm full engagement (eliminates guessing)

  • No threading - simply PUSH ROD (Installs fast and secure)
  • Saves labor costs
  • Fits both 3/8” and 1/2” threaded rod
  • Eliminates the need and cost of couplings

Machined Steel Insert with Large Flanged Head

  • Provides excellent shear values for overhead attachments
  • Insert installed height of two inches can be used through or between ribs
  • Patented grooved insert body prevents component seperation even if the plastic flute is broken off prior to pour

Three Inch Plastic Sleeve

  • Keeps internal threads clean
  • Extended length makes insert easy to locate even with fireproofing below the deck
  • Plastic sleeve provides guidance to align threaded rod with internal auto-lock chamber
  • UL plenum rated for use in air handling spaces